Casement vs. Double-Hung Windows

Free toolWindow Quote Comparison ToolPut up to four installer quotes side by side, line by line: cost per window, what each quote leaves out and what to ask.Compare my quotes →

Casement and double-hung windows open in different ways, and that difference affects air leakage, ventilation, maintenance and code compliance in bedrooms. Here is what our sources support, and where they are silent. Casement window icon

Double-hung window icon

More detail on the up-and-down type is on the double-hung windows page; every type is on the window types hub.

Comparison matrix

Casement Double-hung
How it opens Hinged on the side; swings out or in[Efficient Windows Collaborative] Two sashes slide vertically; top lowers, bottom raises[Efficient Windows Collaborative]
Air leakage Generally lower than sliding windows, because the sash closes by pressing against the frame[DOE] Generally higher than projecting or hinged windows[DOE]
Ventilation choice Not covered by our sources Choose top, bottom or both[Efficient Windows Collaborative]
Weak points to inspect Wind can damage an open sash; hinge damage can stop it closing properly[HUD] In older units, sash weight and balance systems; replacement sashes use spring-loaded jamb liners[U.S. DOE Building America Solution Center]
Where you see them Not covered by our sources Most common type in older homes[The Ohio State University]
Cost data No price split by operating type in NREL’s REMDB 2024 database[NREL REMDB] Same: no price split by operating type[NREL REMDB]
Lifespan Not covered by our sources Not covered by our sources
Appearance Not covered by our sources Not covered by our sources

Key differences

Air leakage

DOE’s Energy Saver pages cited here have been removed from energy.gov; we cite the archived copies. DOE’s archived guidance groups windows into two families. Hinged or projecting types (casement, awning, hopper) close by pressing the sash against the frame and generally leak less; sliding types (single- and double-hung, horizontal sliders) generally leak more.[DOE] DOE adds that leakage for any operable window depends on the weatherstripping and seals and generally increases over time with use.[DOE]

That is a tendency, not a rating. The number to compare is the NFRC air-leakage rating, where lower means less leakage.[ENERGY STAR] ENERGY STAR Version 7.0 (effective October 23, 2023) requires windows of any type to be rated at 0.3 cfm/ft² or lower.[ENERGY STAR]

Exposure and hardware

HUD’s rehab inspection guide (February 2000) singles out casements: when open they are easily damaged by wind, and hinge damage can keep them from closing properly.[HUD] If a window faces strong wind, that is worth weighing. Our sources do not cover crank operators, screens or cleaning access for either type.

Bedroom escape windows

If the window is a bedroom’s emergency escape opening, the 2024 IRC measures the net clear opening as the result of normal operation of the window.[ICC] The minimum is 5.7 square feet (5 square feet at grade floor), with at least 24 inches of height and 20 inches of width.[ICC] Because casements and double-hungs open differently, the same-size frame can give a different clear opening. Ask the supplier for the net clear opening of the exact unit.

When replacing an escape window, the code allows an exemption from some sizing rules if the new window is the manufacturer’s largest standard size that fits, and it may be the same operating style as the old one or a style with equal or greater opening area, as long as the replacement is not part of a change of occupancy.[ICC] Switching a bedroom double-hung to a casement, or the reverse, therefore needs that opening-area check. See egress window requirements for more.

Where the bottom of the opening is less than 24 inches above the floor and more than 72 inches above the ground outside, window fall-protection rules also apply to either type.[ICC] The rule is met either by an opening that will not let a 4-inch-diameter sphere pass through when fully open, or by window opening control or fall prevention devices that comply with ASTM F2090.[ICC] (For replacement windows, see IEBC 702.4 where your jurisdiction applies it.)[ICC]

Cost comparison

Our dated price source, NREL’s REMDB 2024, prices windows by frame class (vinyl, metal, storm) per square foot, not by operating type.[NREL REMDB] We have no source that says casements cost more or less than double-hungs. To compare, get both quoted for the same openings, frame material and glass, then put them side by side in the window quote comparison tool.

Which is right for you?

  1. Is it a bedroom escape window? Get the net clear opening for both options and check it against the code minimums and your local building department.[ICC]
  2. Is lower air leakage a priority? The hinged family generally leaks less[DOE], but compare the actual NFRC air-leakage ratings.[ENERGY STAR]
  3. Will the open sash be exposed to strong wind? Weigh the 2000 HUD inspection guide’s note about wind and hinge damage on casements.[HUD]
  4. Do you want to open the top and bottom separately? That is a double-hung feature.[Efficient Windows Collaborative]
  5. Compare matched quotes for price.

FAQ

Are casement windows more energy efficient than double-hung? DOE’s archived guidance says hinged windows like casements generally leak less air than sliding windows like double-hungs.[DOE] U-factor and SHGC depend on the glass and frame, so compare NFRC labels.[ENERGY STAR]

Can I replace a double-hung with a casement in a bedroom? Under the 2024 IRC replacement provision, the new window keeps the exemption from some sizing rules if it is the manufacturer’s largest standard size that fits and is either the same style or a style with equal or greater opening area, and is not part of a change of occupancy.[ICC] Confirm with your building department.

Which costs more? Our sources don’t price windows by operating type. Get both options quoted.

Sources

  1. U.S. Department of Energy (DOE), Energy Saver. Window Types and Technologies. Accessed 2026-11-24.
  2. Efficient Windows Collaborative (efficientwindows.org, operated by NFRC). Window Types (operating types: single-hung, double-hung, sliding, casement, awning, fixed). Accessed 2026-11-25.
  3. The Ohio State University, Green Home Technology Center. Windows & Skylights (Green Home Technology Center, Passive Design). Accessed 2026-11-24.
  4. U.S. Department of Housing and Urban Development (HUD), Office of Policy Development and Research; prepared by the National Institute of Building Sciences (February 2000). Residential Rehabilitation Inspection Guide (Section 2.3 Windows and Doors; interior window inspection). Accessed 2026-11-24.
  5. ENERGY STAR (U.S. EPA). ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0. Accessed 2026-11-24.
  6. ENERGY STAR (U.S. EPA). Independently Tested and Certified Energy Performance (NFRC label ratings explained). Accessed 2026-11-24.
  7. International Code Council (ICC). 2024 International Residential Code (IRC), Section R319 Emergency Escape and Rescue Openings (R319.1–R319.4: where required, size, sill height, area wells). Accessed 2026-11-24.
  8. International Code Council (ICC). 2024 International Residential Code (IRC), Sections R319.5–R319.7.1: Replacement Windows for Emergency Escape and Rescue Openings, Existing Basements and Existing Openings. Accessed 2026-11-24.
  9. International Code Council (ICC). 2024 International Residential Code (IRC), Section R321.2 Window Fall Protection (R321.2.1 Window Opening Height, R321.2.2 Emergency Escape and Rescue Openings). Accessed 2026-11-24.
  10. National Renewable Energy Laboratory (NREL; site now branded NLR) for the U.S. Department of Energy, via Open Energy Data Initiative (OEDI) submission 8336. National Residential Efficiency Measures Database (REMDB) 2024 — window, storm window and door (fenestration) cost data (2023$). Accessed 2026-11-24.
  11. U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; content by Building Science Corporation). Window Sash Replacement. Accessed 2026-11-24.
  12. International Code Council (ICC). 2024 International Existing Building Code (IEBC) — Replacement Windows: 101.2 Scope Exception, 602.1 Level 1 Alterations, 702.4 Window Fall Prevention, 702.5 Replacement Window for Emergency Escape and Rescue Openings, 505 Windows and Emergency Escape Openings. Accessed 2026-11-24.