Double-hung windows are the familiar up-and-down windows in many American homes. This page explains how they work, how they compare on energy, what your options are when replacing old ones, and the code points to check on bedroom windows. Other operating types and frame materials are on the window types hub.

How a double-hung window works

Double-hung window icon

A double-hung window has two sliding sashes: the top sash can be lowered and the bottom sash raised, so you choose which part of the window to open.[Efficient Windows Collaborative] A single-hung window looks similar, but its top sash is fixed and only the bottom one slides.[Efficient Windows Collaborative] The Ohio State University’s Green Home Technology Center notes that hung windows are the most common type in older homes.[The Ohio State University]

In older wood double-hungs, the sashes are counterbalanced by weights hung on sash cords inside a weight pocket in the frame; the National Park Service notes that replacing sash cords is one of the most common repair items.[U.S. Department of the Interior]

Pros and cons

What our sources say
Ventilation choice Open the top, the bottom, or both[Efficient Windows Collaborative]
Air leakage Sliding windows, including single- and double-hung, generally leak more air than projecting or hinged windows such as casements[DOE]
Leakage over time DOE’s archived Energy Saver guidance says air leakage of any operable window depends on weatherstripping and seals and generally increases with use[DOE]
Familiar in older homes Most common type in older homes[The Ohio State University]

DOE’s Energy Saver pages cited here have been removed from energy.gov; we cite the archived copies. | Tightness at the meeting rail | NPS recommends sash locks on the meeting rail so the sashes stay tightly closed and the weatherstripping works[U.S. Department of the Interior] |

Replacing old double-hung windows: three approaches

Approach What stays Sash weights Trade-offs
Sash replacement Existing frame Replaced with a spring-loaded jamb liner; weight pockets can then be retrofitted[U.S. DOE Building America Solution Center] Custom-built sashes and tight tolerances; loose work causes significant air leakage; in large windows the liner can be up to an inch thick and may reduce visible window area[U.S. DOE Building America Solution Center]
Insert replacement Original frame[Efficient Windows Collaborative] Abandoned; weights removed and the cavity air sealed and insulated[U.S. DOE Building America Solution Center] The added frame reduces vision area, which can be significant on small windows[U.S. DOE Building America Solution Center]; sill and frame must be sound[Efficient Windows Collaborative]
Complete replacement Nothing; back to the rough framing, often including casing and trim[U.S. DOE Building America Solution Center] Removed (cast-iron weights recycled), cavities air sealed and insulated[U.S. DOE Building America Solution Center] Highest performance but most intrusive and expensive option[U.S. DOE Building America Solution Center]

Whichever you choose, DOE Building America guidance says cracked or rotting sills must be replaced before any option short of complete replacement.[U.S. DOE Building America Solution Center]

What double-hung windows cost

Our dated price source, NREL’s REMDB 2024, does not split prices by operating type: it has vinyl, metal and storm window classes only, priced per square foot of window in 2023 dollars.[NREL REMDB] The vinyl figures are on our vinyl windows page. For a double-hung quote, the main cost questions are:

Compare bids line by line in the window quote comparison tool.

Energy performance

Because hung windows tend to leak more air than hinged types,[DOE] look closely at the air-leakage rating. ENERGY STAR Version 7.0 (effective October 23, 2023) requires windows to be rated at 0.3 cfm/ft² or lower.[ENERGY STAR] Also compare the NFRC U-factor (lower insulates better) and SHGC (lower blocks more solar heat).[ENERGY STAR]

Bedroom windows and code

If the double-hung window is a bedroom’s emergency escape opening, a few 2024 International Residential Code points apply:

Local codes vary; confirm with your building department.

When to call a professional

Sash replacement is workmanship-sensitive with tight tolerances.[U.S. DOE Building America Solution Center] The Efficient Windows Collaborative points to complete replacement when the old frame is deteriorated, significantly out of square, or a larger opening is needed.[Efficient Windows Collaborative] A cracked or rotting sill has to be replaced before an insert goes in.[U.S. DOE Building America Solution Center]

Sources

  1. U.S. Environmental Protection Agency, Code of Federal Regulations (eCFR, Title 40). 40 CFR Part 745, Subpart E—Residential Property Renovation (RRP Rule): §§ 745.80–745.84 (Purpose, Effective Dates, Applicability, Definitions, Information Distribution) and selected § 745.103 definitions (target housing). Accessed 2026-11-24.
  2. Efficient Windows Collaborative (efficientwindows.org, operated by NFRC). Window Types (operating types: single-hung, double-hung, sliding, casement, awning, fixed). Accessed 2026-11-25.
  3. U.S. Department of Energy (DOE), Energy Saver. Window Types and Technologies. Accessed 2026-11-24.
  4. The Ohio State University, Green Home Technology Center. Windows & Skylights (Green Home Technology Center, Passive Design). Accessed 2026-11-24.
  5. U.S. Department of Housing and Urban Development (HUD), Office of Policy Development and Research; prepared by the National Institute of Building Sciences (February 2000). Residential Rehabilitation Inspection Guide (Section 2.3 Windows and Doors; interior window inspection). Accessed 2026-11-24.
  6. U.S. Department of the Interior, National Park Service, Technical Preservation Services (John H. Myers, 1981). Preservation Briefs 9: The Repair of Historic Wooden Windows. Accessed 2026-11-24.
  7. U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; content by Building Science Corporation). Window Sash Replacement. Accessed 2026-11-24.
  8. U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; content by Building Science Corporation). Insert Replacement Window. Accessed 2026-11-24.
  9. U.S. DOE Building America Solution Center (Pacific Northwest National Laboratory; content by Building Science Corporation). Complete Window and Frame Replacement. Accessed 2026-11-24.
  10. Efficient Windows Collaborative (efficientwindows.org, operated by NFRC). Insert Replacement Windows vs Full Window Replacement. Accessed 2026-11-24.
  11. ENERGY STAR (U.S. EPA). Independently Tested and Certified Energy Performance (NFRC label ratings explained). Accessed 2026-11-24.
  12. ENERGY STAR (U.S. EPA). ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0. Accessed 2026-11-24.
  13. International Code Council (ICC). 2024 International Residential Code (IRC), Section R319 Emergency Escape and Rescue Openings (R319.1–R319.4: where required, size, sill height, area wells). Accessed 2026-11-24.
  14. International Code Council (ICC). 2024 International Residential Code (IRC), Sections R319.5–R319.7.1: Replacement Windows for Emergency Escape and Rescue Openings, Existing Basements and Existing Openings. Accessed 2026-11-24.
  15. International Code Council (ICC). 2024 International Residential Code (IRC), Section R321.2 Window Fall Protection (R321.2.1 Window Opening Height, R321.2.2 Emergency Escape and Rescue Openings). Accessed 2026-11-24.
  16. National Renewable Energy Laboratory (NREL; site now branded NLR) for the U.S. Department of Energy, via Open Energy Data Initiative (OEDI) submission 8336. National Residential Efficiency Measures Database (REMDB) 2024 — window, storm window and door (fenestration) cost data (2023$). Accessed 2026-11-24.
  17. U.S. Environmental Protection Agency (EPA). Renovation, Repair and Painting (RRP) Program: Consumers. Accessed 2026-11-24.
  18. U.S. Environmental Protection Agency (EPA). Renovation, Repair and Painting Program: Contractors. Accessed 2026-11-24.
  19. International Code Council (ICC). 2024 International Existing Building Code (IEBC) — Replacement Windows: 101.2 Scope Exception, 602.1 Level 1 Alterations, 702.4 Window Fall Prevention, 702.5 Replacement Window for Emergency Escape and Rescue Openings, 505 Windows and Emergency Escape Openings. Accessed 2026-11-24.